Sequence Of Events Recorder

The OrionLX or LXm with the Alarm Archive Retentive software option can act as a substation Sequence of Events Recorder. Selected analog and discrete data from substation meters, event recorders, relays and other IEDs is time-stamped to 1 millisecond using IRIG-B. These data are stored in non-volatile memory in the OrionLX’s resident SQL database. Time-Stamped event records can be provided to SCADA, Engineering, Web and Mobile Clients via a Sequence of Events tabular webpage, a CSV file transfer or in response to SQL Queries.

Software for this Application

Alarm/Archive/Retentive

Stores both discrete and analog events based on time (e.g. every 15 minutes) or change (e.g. ON-OFF or analog change out of deadband). Alarm Annunciation functionality includes defining alarm states, defining alarm messages. Pre-engineered “Archive” and “Alarm” webpages included.

PostgreSQL

Open object-relational database management system (ORDBMS) used in the OrionLX to store SOE points, Alarms, Tags, and files in non-volatile Expanded Memory.

FileMover

Enables user-selected files (relay records, .csv SOE files, etc.) to be automatically transferred from the OrionLX to a remote FTP site using FTP or SFTP.

OrionLX Hardware Features for this Application

IRIG B Port

50 Ohm coax port receives modulated or unmodulated IRIG-B. IRIG-B can be passed through to serial ports, or if no source, generated.

1GB or 4GB Expanded Memory

Expanded Flash Memory with PostgreSQL Relational Database (4GB included with the High Performance CPU).

OrionLXm Hardware Features for this Application

IRIG B Port

Twisted pair unmodulated IRIG-B. IRIG-B can be passed through to serial ports, or if no source, generated.

4GB Expanded Memory

Expanded Flash Memory – 4GB with PostgreSQL Relational Database.

    June 21, 2017 – June 22, 2017 Fayetteville Public Works Commission

    2017 North Carolina Technical Symposium

    NovaTech in cooperation with Criterion, Inc. invites you to our 2017 North Carolina Users’ Group Meeting and Technical Symposium to be held on Thursday, June 22, 2017, hosted by Fayetteville Public...

    June 27, 2017 Doubletree Hotel - Overland Park

    2017 Kansas Technical Symposium

    Please register to attend the upcoming Kansas Technical Symposium in Overland Park. Come and see presentations on Orion I/O, Orion Redundancy, Bitronics M650, PowerPlex II with I/O, and Bitronics M87X...

    July 12, 2017 Doubletree Cedar Rapids

    2017 Iowa Technical Symposium

    Please register to attend the upcoming Iowa Technical Symposium in Cedar Rapids. Come and see presentations on Orion I/O, Orion Redundancy, Bitronics M650, PowerPlex II with I/O, and Bitronics M87X...

  • NovaTech Utility Systems and Services

    Almost half of NovaTech’s business is in Systems and Services including web page design, panel design, math and logic development, Orion configuration, and onsite installation and commissioning. Mark Matassa explains how our engineers can work with you to reduce project execution time at the 2016 DistribuTECH Conference and Exhibition in Orlando, Florida.

    March 18, 2016

  • Sequence Of Events Recorder

    The OrionLX or LXm with the Alarm Archive Retentive software option can act as a substation Sequence of Events Recorder

    September 17, 2014

Your browser is out-of-date!

Update your browser to view this website correctly.Update my browser now

×